⚠️ SAFETY WARNING / SERIOUS RISK. This air conditioner operates with 230V mains voltage and high residual DC voltages (up to 340V DC) on the electronic board, in addition to containing fluorinated refrigerant gas. Any electrical or mechanical intervention requires disconnecting the dedicated general miniature circuit breaker. DIY repair is extremely dangerous and prohibited by law (F-Gas regulation and DM 37/08). ReeFix provides this diagnosis for informational purposes only.
The Daikin FTXM35R device displays error code A6. This specifically indicates an anomaly in the indoor unit's fan motor. The self-diagnosis system detects a mechanical blockage, an overcurrent, or the absence of the tachometric feedback signal from the motor itself. The indoor unit ceases to function correctly, not delivering airflow.
The diagnosis for error A6 on the Daikin FTXM35R focuses on the indoor unit's motor/fan assembly and its control electronics. The BLDC (Brushless Direct Current) motor requires constant feedback to the microprocessor to operate. The absence or anomaly of this signal, or an impediment to rotation, activates the A6 protection.
In many cases, before error A6 becomes permanent, you might notice the fan spinning very slowly or intermittently. This abnormal behavior confirms that the motor is losing its internal synchronization signal and needs to be replaced.
* **Quick checks:** With the machine disconnected, try to spin the fan by hand. If it is free, reconnect and, with a professional multimeter, check for the presence of Vm (~280-340V DC) and Vcc (15V DC) voltages on the connector on the motherboard side that powers the motor. If present, the fault is in the motor.
* **Estimated cost:** Replacing the [Daikin FTXM35R Indoor Fan Motor](https://www.ebay.it/sch/i.html?_nkw=Daikin+FTXM35R+Indoor+Fan+Motor&mkcid=1&mkrid=724-53478-19255-0&siteid=101&campid=5339148621&toolid=10001&mkevt=1) (spare part + labor) can range from 180 to 350 euros. This is the most common case, and repair is almost always cost-effective.
2. Malfunction of the Daikin FTXM35R Indoor Unit Electronic Board (IPM drive circuit) — 20-25% * Key signals: The unit does not provide the correct voltages to the motor. Measuring on the motherboard connector, the absence of Vm or Vcc voltage is detected, or the speed command signal (Vsp, 0-6V DC) is absent or anomalous. The IPM power module or filter capacitors on the board are often responsible. * Quick checks: Disconnect the motor and, with a Professional Digital Multimeter, measure the voltage outputs directly on the motherboard pins during power-on. If Vm or Vcc voltages are absent or unstable, the board is compromised. * Estimated cost: Replacing the Daikin FTXM35R Indoor Unit Electronic Board is more expensive, from 250 to 500 euros. Even in this case, repair is often justified.
Mechanical obstruction or wear of fan bearings/bushings — 5-10%
Unstable connector or broken wiring — <5%
Real micro-case: Often, in units installed in humid environments or with poor maintenance, the accumulation of a gelatinous film of mold and dust on the tangential fan drastically increases its weight and friction, simulating an electrical fault and activating A6. A deep cleaning, performed by a technician, solves the problem.
Operational decision: If the fan rotates freely by hand, but the motor does not start and Vm and Vcc voltages are present on the connector, contact a technician for the replacement of the Daikin FTXM35R Indoor Fan Motor; if Vm or Vcc voltages are absent, a fault in the Daikin FTXM35R Indoor Unit Electronic Board is likely, requiring professional intervention.