climatizzatore

⚠️ SAFETY WARNING / SERIOUS RISK. This appliance operates with critically dangerous components (High Voltage or Gas). DIY repair of critical devices can be fatal and is prohibited by law. Physical intervention legally requires qualified specialized technicians to issue compliant safety certificates. ReeFix provides this diagnosis EXCLUSIVELY for educational and informational purposes.

Diagnosis LG S18ET NSJ Dualcool Smart: CH05 Errors and CH06

CH05 (communication error between indoor and outdoor units) and CH06 (NTC heat exchanger sensor anomaly of the indoor unit) errors on LG Dualcool Smart (S18ET NSJ) are closely related. The most probable cause (55-60%) for both is a fault or thermal drift of an NTC sensor for the indoor unit heat exchanger of an LG Dualcool Smart (S18ET NSJ)&mkcid=1&mkrid=711-53200-19255-0&siteid=0&campid=5339148621&toolid=10001&mkevt=1). A blockage due to the CH06 code can indeed interrupt correct serial communication, generating the CH05 code in cascade.

When the CH06 error occurs, the LG air conditioner suddenly stops and often shows six consecutive flashes on the split's LED. This behavior indicates that the sensor no longer correctly detects the evaporator temperature, preventing the air conditioning cycle from starting for safety.

Less probable is a problem with the interconnection wiring between the two units (25-30%) or a fault in the external electronic board for LG Dualcool Smart (S18ET NSJ)&mkcid=1&mkrid=711-53200-19255-0&siteid=0&campid=5339148621&toolid=10001&mkevt=1) (10-15%). Prolonged exposure to humidity and temperature fluctuations often deteriorates sensors or oxidizes wiring contacts. A professional Fluke digital multimeter is essential for measuring sensor resistance and verifying communication voltage on the serial line.

Operational decision: For your safety and the complexity of the intervention, which involves mains voltages and refrigerant gases, always contact a qualified technician. DIY is discouraged and potentially dangerous. Replacing the entire air conditioner is rarely necessary for these codes, as repair by replacing the sensor or restoring the wiring is highly cost-effective and efficient.

Caricamento interfaccia di diagnosi...
About Us|Privacy Policy|Terms of Service|Cookie Policy
© 2026 Reefix. All rights reserved.Reefix™ is an independent AI diagnostic platform. All third-party names, logos, and brands (including those of the appliance manufacturers described) are the property of their respective owners and used strictly for descriptive, informative, and compatibility purposes. Reefix participates in the eBay Partner Network and the Amazon EU Associates Program: as an Amazon Associate and eBay Partner, we earn from qualifying purchases made through our links, at no extra cost to the user.
The listed partner professionals are independent entities. ReeFix acts exclusively as a referral platform and declines any liability for the services they provide.
🚀 Launched April 1, 2026
Chia Luca  |  P.IVA IT01433480991  |  Sede Legale: Via Filippo Casoni 4a r, Genova (GE) Italia  |  Reefix™ è un marchio depositato di Luca Chia.
[email protected]  |  +39 389 630 3148
AI can make mistakes. Always verify important information with a professional if you are unsure of your skills.
© 2026 Reefix. All rights reserved. |  P.IVA IT01433480991  | [email protected]