Electronic Technical Report issued on: 08/08/2026
⚠️ SAFETY WARNING / SERIOUS RISK. This appliance operates with high-voltage components (up to 380V DC in the external inverter board capacitors, even after shutdown) and R32 refrigerant gas under pressure. DIY repair of these systems is extremely dangerous, can be fatal, and is prohibited by law (F-Gas regulation). Any physical intervention requires the involvement of qualified and certified technicians. ReeFix provides this diagnosis EXCLUSIVELY for educational and informational purposes.
The appearance of E1 and E4 errors on the Midea Mission II MSMABU-09HRDN8 air conditioner indicates two distinct but potentially related anomalies that block the system's operation. Error E1 signals a lack of communication between the indoor unit and the outdoor unit, while error E4 indicates a fault (open circuit or short circuit) of the indoor unit's ambient temperature sensor (T1 sensor).
When these two codes appear together or in rapid succession, the main cause is usually related to a power supply problem or a fault on the indoor unit's electronic board, which manages both serial communication and internal sensor readings.
Immediate decision: In most cases, the intervention of a qualified technician is essential. As these are electronic and communication anomalies that require instrumental tests under voltage and verification of internal components, DIY is highly discouraged and dangerous.
Here is a detailed analysis of the most frequent causes for these errors on the Midea Mission II, ordered by probability:
E1 Error: Serial communication interruption (Wiring or Outdoor/Indoor Board) — 50%
60-120 euros. If the cause is irreversible damage to the communication circuits, replacement of the Midea Mission II Outdoor Electronic Board may be necessary: 250-500 euros (original spare part and labor included).E4 Error: Fault or disconnection of the internal ambient temperature sensor T1 — 30%
50-100 euros (spare part and labor).Fault on the indoor unit electronic board (Indoor PCB) — 20%
180-320 euros (spare part and labor).DIY repair: Not recommended and potentially dangerous. Resolving serial communication problems and diagnosing sensors requires opening the units, exposure to live parts, and the use of professional measuring instruments.
What NOT to do yourself:
What a careful user can do (with caution):
Contacting a technician: STRONGLY RECOMMENDED. A specialized technician has the necessary instrumentation, such as a Testo digital manifold gauge to verify R32 gas operating pressures if the communication block is related to pressure protections, and official Midea electrical diagrams to safely test electronic components.
Synthetic output for the technician: "Midea Mission II MSMABU-09HRDN8 air conditioner with E1 and E4 errors. Verification of serial communication on the S line (oscillating DC voltage) and control of the resistive value of the internal ambient temperature sensor T1 (nominal 10 kOhm at 25°C) is required. Exclude power supply faults on the indoor board (Indoor PCB) or damage to the external inverter board."
The economic evaluation depends on the precise diagnosis made by the technician:
50-120 euros). In this case, repair is highly convenient and extends the device's useful life.180-320 euros, repair is still convenient if the air conditioner is less than 6-8 years old and in good general condition.250-500 euros. As this is a mid-range inverter model, if the appliance is more than 8 years old, the expense could approach 50-60% of the cost of an equivalent new air conditioner (whose purchase price usually ranges between 400-800 euros, excluding installation).Operational decision: If the technician's analysis highlights a problem with the T1 sensor or a simple wiring defect, proceed immediately with the repair. If, however, serious damage to the external electronic board is found on an old system, consider purchasing a new high-efficiency model to also benefit from current tax deductions and a new total warranty.