Electronic Technical Report issued on: 10/25/2026
⚠️ SAFETY WARNING / ELECTRICAL RISK. Before performing any physical work on the dishwasher, disconnect the 230V power supply via the main circuit breaker and turn off the water tap to prevent electric shock or flooding. ReeFix provides this diagnosis EXCLUSIVELY for educational and informational purposes.
Error F13 indicates a water fill timeout: the control board expects filling within 2-4 minutes, but the flow rate is insufficient.
This often happens when... after work on the local water network or prolonged periods of disuse, debris is pushed directly against the solenoid valve mesh filter, blocking up to 80% of the water flow.
If the wall pressure is correct and the filter is clean, the fault lies in the measuring or flow-opening components.
Aquastop Solenoid Valve Test (WPS):
Flow Meter and Air Gap Side Matrix Inspection:
If during the fill cycle the dishwasher shows anomalies related to pressure or the level pressure switch, also consult our diagnosis on Miele G 4203 SC Error F14: Diagnosis and Solution.
Summary for your trusted technician:
Error code F13 on Miele G5210SC. Wall tap pressure verified. Check resistance value on double WPS solenoid (expected ~2.2 kΩ) and switching continuity of the flow meter reed sensor on the air matrix.
Reassemble the components, turn the water tap back on, and start a short rinse cycle. Make sure the initial count does not stall and water fills normally within 60 seconds of starting without triggering alarm F13 again.
If cleaning the inlet filter does not resolve the alarm -> check WPS assembly resistance: if winding is open, replace the Miele G5210SC Aquastop WPS inlet hose; otherwise, replace the Miele G5210SC Reed flow meter sensor.