Electronic Technical Report issued on: 06/18/2026
WARNING: Electrical risk! This air conditioner operates at 230V. Any physical intervention on internal components is extremely dangerous. Before removing the front panel, it is imperative to disconnect the power by deactivating the main circuit breaker. It is strongly recommended to rely on a qualified refrigeration technician. ReeFix provides this diagnosis EXCLUSIVELY for educational and informational purposes.
Probability: Absolute (100% for the "not heating" symptom). Why it happens: There is a fundamental misunderstanding behind the "not heating" symptom. In Olimpia Splendid nomenclature, the acronym SF stands for Cool Only. Unlike "HP" (Heat Pump) models, your Unico Tower SF is physically devoid of the 4-way valve and reversible refrigeration circuit necessary to produce hot air. Key signs/indicators:
Probability: High (65-75% for the appearance of F2 error). Why it happens: The F2 error on Olimpia Splendid systems is not related to lack of heating, but signals an anomaly (open or short circuit) of an NTC temperature sensor (usually the ambient probe or the evaporator coil probe). The motherboard detects an out-of-range value and blocks the machine to prevent compressor damage. Key signs/indicators:
Probability: Low (10-20%). Why it happens: If the NTC sensor tests perfectly with the multimeter, the problem lies in data communication. The cables might have been damaged (e.g., vibrations) or the motherboard suffered a power surge that burned out the analog-to-digital reading circuit, generating a false F2 error. Key signs/indicators:
The diagnosis for this case is divided into two fundamental parts. First, your Olimpia Splendid Unico Tower SF will never heat because it is a "Cool Only" model, lacking a heat pump. Any attempt to force heating is futile. Regarding the total lockout with F2 error, the most probable cause is a faulty NTC temperature sensor. As it is an economical repair (20-50€ for the spare part), we recommend contacting a technician for sensor replacement. Only in the less probable case where the technician diagnoses an irreversible fault with the control board (PCB), you will need to evaluate whether the high cost of repair (over 200-300€) is justified compared to purchasing a new unit, perhaps opting this time for an "HP" model if you also desire the heating function.