Electronic Technical Report issued on: 11/06/2026
⚠️ SAFETY WARNING: Disconnect the power plug before any intervention. Testing 230V circuits and high-power components carries severe risks of electrocution and must be conducted with appropriate protection. ReeFix provides this diagnosis EXCLUSIVELY for educational and informational purposes.
Codes C24 and C25 indicate an interruption or anomaly in the power supply chain of the 1000W mixing bowl heating element.
| Component Under Test | Expected Value / Status | Corrective Action | | :--- | :--- | :--- | | Bowl Heating Element | ~50 - 55 Ω between pins | Contact cleaning or bowl replacement | | Housing Spring Contacts | Clean, unoxidized, reactive | Treatment with dry contact cleaner spray | | Board Power Relay | Continuity upon switching (12VDC) | Desoldering and replacement of burnt relays |
If the bowl resistance is correct (~50Ω) but heating fails -> replace the power relays (or the entire board); otherwise restore the bowl contacts.
If you are facing electronic issues on another model of the same brand, you can check our dedicated diagnosis for Vorwerk Bimby TM6 Error C153: Diagnosis and Solution.