Electronic Technical Report issued on: 10/27/2026
⚠️ SAFETY WARNING / ELECTRICAL HAZARD. Before performing any operation or physical diagnosis on this appliance, disconnect the power supply by turning off the main circuit breaker on the electrical panel. Servicing internal components of the induction hob requires specific skills and involves risks from high voltage and residual charges in capacitors; if you do not have the necessary experience, contact a qualified technician. ReeFix provides this diagnostic report solely for educational, informational, and study purposes.
Error codes FE 31 and FE 32 indicate a power supply anomaly or a communication failure on the power module's DC bus. The main cause often lies in thermal stress accumulated inside the cabinet cavity due to insufficient under-counter ventilation.
Causes and probabilities:
For measuring voltages and continuity, use a True RMS digital multimeter; in case of extensive damage to the track or SMD components, replacement with a new power module for induction hob is required.
Operational decision: First, check the MKP filter capacitors (65% cause): if the ESR value is altered with a capacitance drop >15%, replace the capacitor kit. If the SMPS stage components or IGBTs are irremediably damaged, proceed with the complete replacement of the power module.
If you are facing electronic issues on appliances of the same brand, also check our diagnostic report on Miele TWI180WP: Error F18 and Repair Solutions.